ATV630U22N4

Schneider Electric

Variable speed drive ATV630

2.2kW/3HP – 380…480V – IP21/UL type 1

 

 

Compare
Main
range of product
Altivar Process ATV600
product or component type
Variable speed drive
product specific application
Process and utilities
device short name
ATV630
variant
Standard version
product destination
Asynchronous motors
Synchronous motors
EMC filter
Integrated with 50 m conforming to EN/IEC 61800-3 category C2
Integrated with 150 m conforming to EN/IEC 61800-3 category C3
IP degree of protection
IP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529
degree of protection
UL type 1 conforming to UL 508C
type of cooling
Forced convection
supply frequency
50…60 Hz – 5…5 %
network number of phases
3 phases
[Us] rated supply voltage
380…480 V – 15…10 %
motor power kW
2.2 kW (normal duty)
1.5 kW (heavy duty)
motor power hp
3 hp normal duty
2 hp heavy duty
line current
4.3 A at 380 V (normal duty)
3.8 A at 480 V (normal duty)
3.1 A at 380 V (heavy duty)
2.9 A at 480 V (heavy duty)
prospective line Isc
50 kA
apparent power
3.2 kVA at 480 V (normal duty)
2.4 kVA at 480 V (heavy duty)
continuous output current
5.6 A at 4 kHz for normal duty
4 A at 4 kHz for heavy duty
maximum transient current
6 A during 60 s (heavy duty)
6.2 A during 60 s (normal duty)
asynchronous motor control profile
Constant torque standard
Optimized torque mode
Variable torque standard
synchronous motor control profile
Permanent magnet motor
Synchronous reluctance motor
Output frequency
0.0001…0.5 kHz
speed drive output frequency
0.1…599 Hz
nominal switching frequency
4 kHz
switching frequency
2…12 kHz adjustable
4…12 kHz with derating factor
safety function
STO (safe torque off) SIL 3
discrete input logic
16 preset speeds
communication port protocol
Modbus TCP
Modbus serial
Ethernet
option card
Slot A: communication module, Profibus DP V1
Slot A: communication module, Profinet
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Complementary
output voltage
<= power supply voltage
permissible temporary current boost
1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
motor slip compensation
Automatic whatever the load
Adjustable
Not available in permanent magnet motor law
Can be suppressed
acceleration and deceleration ramps
Linear adjustable separately from 0.01…9999 s
braking to standstill
By DC injection
protection type
Thermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control: removable screw terminals0.5…1.5 mm²/AWG 20…AWG 16
Motor: screw terminal2.5…6 mm²/AWG 14…AWG 10
Line side: screw terminal2.5…6 mm²/AWG 14…AWG 10
connector type
RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
exchange mode
Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
data format
8 bits, configurable odd, even or no parity for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave Modbus TCP
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
local signalling
3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
144 mm
height
350 mm
depth
203 mm
net weight
4.5 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA/4…20 mA, impedance: 250 Ohm, resolution 12 bits
discrete input number
8
discrete input type
DI1…DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
input compatibility
DI1…DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
discrete input logic
Positive logic (source) (DI1…DI6), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1…DI6), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1)
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
analogue output number
2
analogue output type
Software-configurable voltage AO1, AO2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AO1, AO2: 0…20 mA, resolution 10 bits
sampling duration
2 ms +/- 0.5 ms (DI1…DI4) – discrete input
5 ms +/- 1 ms (DI5, DI6) – discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
10 ms +/- 1 ms (AO1) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AO1, AO2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
Variable speed drive application selection
Compressor centrifugal Building – HVAC
Other application Food and beverage processing
Fan Mining mineral and metal
Pump Mining mineral and metal
Fan Oil and gas
Other application Water and waste water
Screw compressor Building – HVAC
Pump Food and beverage processing
Fan Food and beverage processing
Atomization Food and beverage processing
Electro submersible pump (ESP) Oil and gas
Water injection pump Oil and gas
Jet fuel pump Oil and gas
Compressor for refinery Oil and gas
Centrifuge pump Water and waste water
Positive displacement pump Water and waste water
Electro submersible pump (ESP) Water and waste water
Screw pump Water and waste water
Lobe compressor Water and waste water
Screw compressor Water and waste water
Compressor centrifugal Water and waste water
Fan Water and waste water
Conveyor Water and waste water
Mixer Water and waste water
Motor power range AC-3
2.2…3 kW at 380…440 V 3 phases
2.2…3 kW at 480…500 V 3 phases
mounting mode
Wall mount
Environment
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
54.5 dB conforming to 86/188/EEC
power dissipation in W
Natural convection: 30 W at 380 V, switching frequency 4 kHz
Forced convection: 60 W at 380 V, switching frequency 4 kHz
volume of cooling air
38 m3/h
operating position
Vertical +/- 10 degree
maximum THDI
<48 % full load conforming to IEC 61000-3-12
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…50 °C (without derating)
50…60 °C (with derating factor)
ambient air temperature for storage
-40…70 °C
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
UL 508C
EN/IEC 61800-3
Environment 1 category C2 EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
product certifications
ATEX INERIS
CSA
ATEX zone 2/22
REACH
TÜV
UL
DNV-GL
marking
CE
Packing Units
Package 1 Weight
5.939 kg
Package 2 Weight
48.63 kg
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty
18 months
Brands

Schneider Electric

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “ATV630U22N4”

There are no reviews yet.

SHOPPING CART

close