range of product |
Altivar Machine ATV320 |
|
---|---|---|
product or component type |
Variable speed drive |
|
product specific application |
Complex machines |
|
variant |
Standard version |
|
mounting mode |
Wall mount |
|
communication port protocol |
Modbus serial CANopen |
|
option card |
Communication module, CANopen Communication module, EtherCAT Communication module, Profibus DP V1 Communication module, Profinet Communication module, Ethernet Powerlink Communication module, Ethernet/IP Communication module, DeviceNet |
|
[Us] rated supply voltage |
380…500 V – 15…10 % |
|
[Us] rated supply voltage |
380…500 V |
|
relative symmetric mains voltage tolerance |
10 % |
|
relative symmetric network frequency tolerance |
5 % |
|
nominal output current |
14.3 A |
|
motor power kW |
5.5 kW for heavy duty |
|
EMC filter |
Class C2 EMC filter integrated |
|
IP degree of protection |
IP20 |
discrete input number |
7 |
|
---|---|---|
discrete input type |
STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1…DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V) |
|
discrete input logic |
Positive logic (source) Negative logic (sink) |
|
discrete output number |
3 |
|
discrete output type |
Open collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA |
|
analogue input number |
3 |
|
analogue input type |
AI1 voltage: 0…10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
|
analogue output number |
1 |
|
analogue output type |
Software-configurable current AQ1: 0…20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits |
|
relay output type |
Configurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C |
|
maximum switching current |
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC |
|
minimum switching current |
Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC |
|
method of access |
Slave CANopen |
|
4 quadrant operation possible |
True |
|
asynchronous motor control profile |
Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio – Energy Saving, quadratic U/f Flux vector control without sensor – Energy Saving Voltage/frequency ratio, 2 points |
|
synchronous motor control profile |
Vector control without sensor |
|
maximum output frequency |
0.599 kHz |
|
transient overtorque |
170…200 % of nominal motor torque |
|
acceleration and deceleration ramps |
Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection |
|
motor slip compensation |
Automatic whatever the load Adjustable 0…300 % Not available in voltage/frequency ratio (2 or 5 points) |
|
switching frequency |
2…16 kHz adjustable 4…16 kHz with derating factor |
|
nominal switching frequency |
4 kHz |
|
braking to standstill |
By DC injection |
|
brake chopper integrated |
True |
|
line current |
20.7 A at 380 V (heavy duty) 14.5 A at 500 V (heavy duty) |
|
maximum input current |
20.7 A |
|
maximum output voltage |
500 V |
|
apparent power |
12.6 kVA at 500 V (heavy duty) |
|
network frequency |
50…60 Hz |
|
prospective line Isc |
22 kA |
|
base load current at high overload |
14.3 A |
|
power dissipation in W |
Fan: 195.0 W at 380 V, switching frequency 4 kHz |
|
with safety function Safely Limited Speed (SLS) |
True |
|
with safety function Safe brake management (SBC/SBT) |
False |
|
with safety function Safe Operating Stop (SOS) |
False |
|
with safety function Safe Position (SP) |
False |
|
with safety function Safe programmable logic |
False |
|
with safety function Safe Speed Monitor (SSM) |
False |
|
with safety function Safe Stop 1 (SS1) |
True |
|
with sft fct Safe Stop 2 (SS2) |
False |
|
with safety function Safe torque off (STO) |
True |
|
with safety function Safely Limited Position (SLP) |
False |
|
with safety function Safe Direction (SDI) |
False |
|
protection type |
Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive |
|
width |
150 mm |
|
height |
232.0 mm |
|
depth |
178.0 mm |
|
net weight |
3.5 kg |
operating position |
Vertical +/- 10 degree |
|
---|---|---|
product certifications |
CE ATEX NOM GOST EAC RCM KC REACH |
|
marking |
CE ATEX UL CSA EAC RCM |
|
electromagnetic compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
|
environmental class (during operation) |
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
|
maximum acceleration under shock impact (during operation) |
150 m/s² at 11 ms |
|
maximum acceleration under vibrational stress (during operation) |
10 m/s² at 13…200 Hz |
|
maximum deflection under vibratory load (during operation) |
1.5 mm at 2…13 Hz |
|
permitted relative humidity (during operation) |
Class 3K5 according to EN 60721-3 |
|
volume of cooling air |
60 m3/h |
|
overvoltage category |
III |
|
regulation loop |
Adjustable PID regulator |
|
speed accuracy |
+/- 10 % of nominal slip 0.2 Tn to Tn |
|
pollution degree |
2 |
|
ambient air transport temperature |
-25…70 °C |
|
ambient air temperature for operation |
-10…50 °C without derating 50…60 °C with derating factor |
|
ambient air temperature for storage |
-25…70 °C |
Package 1 Weight |
4.689 kg |
|
---|---|---|
Package 2 Weight |
57.5 kg |
Sustainable offer status |
Green Premium product |
|
---|---|---|
REACh Regulation |
REACh Declaration |
|
EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration |
|
Mercury free |
Yes |
|
RoHS exemption information |
Yes |
|
China RoHS Regulation |
China RoHS declaration |
|
Environmental Disclosure |
Product Environmental Profile |
|
Circularity Profile |
End of Life Information |
|
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty |
18 months |
---|