Specifications
- Input
- Analog outputs: Analog inputs: Two standard isolated inputs filtered with transient protection, 4–20 mA (user scalable and assignable)
Digital inputs: Five inputs, user assignable, optically isolated, rated to 30V DC @ 0.5 A
- Output
- Analog outputs: Six self-powered isolated outputs (4–20 mA)
Digital outputs: Five user-assignable outputs, Form C and electromechanically isolated, 24V DC
- Communication Protocol
- Ethernet: Two ports – one RJ-45 and one four-wire – with 10/100 mbps
Serial: Three termination blocks, configurable as RS-232, RS-422 or RS-485 and one RS-232 D-sub (9-pin) Modbus/PC Connection
- Power Supply
- Standard: 24V DC (21–30 VDC)
Optional: 90–264V AC, 47–63 Hz
- Certificates/Approvals
- CSA for USA: Class I, Zone 1, AEx d IIC, Enclosure Type 4. Class I, Division 1, Groups B, C, and D, IP66
CSA for CANADA: Class I, Zone 1, Ex d IIC, Enclosure Type 4. Class I, Division 1, Groups B, C, and D, IP66
ATEX / IECEx. Ex II 2G. Ex d IIC Gb T6. (Ta = -20 °C to 60 °C)
- Dimensions
- Wall-mount: 711 mm H x 445 mm W x 498 mm D (28″ H x 17.5″ W x 19.6″ D)
Pipe-mount: 711 mm H x 445 mm W x 671 mm D (28″ H x 17.5″ W x 26.4″ D)
Floor-mount: 1532 mm H x 445 mm W x 612 mm D (60.3″ H x 17.5″ W x 24.1″ D)
- Mounting
- Floor-standing (standard), wall- or pipe-mount (optional)
- Weight
- 50 kg (110 lbs.)
Features
- Industry’s first transmitter-style gas chromatograph capable of combining the measurement of natural gas energy content, hydrogen sulfide, speciation of total sulfur compounds to trace levels, and hydrocarbon dew point (HCDP) calculations in a single-analyzer solution
- Explosion-proof and ATEX/IECEX safety rating enables field installation without enclosure even in Class 1, Division 1 areas
- No instrument air for purge or oven required, reducing power consumption over traditional air purged GC units
- Secure, remote operation capabilities enable audit checks and reduce the need to attend remote locations
- Wide dynamic measurement ranges from percent to trace-level components
- Micro flame photometric detector (µFPD) and micro flame ionization detector (µFID) sensitive to parts-per-billion levels
- Thermal conductivity detector (TCD) sensitive down to low parts-per-million levels
- Reliable performance over broad ambient temperatures -20 °C to 60 °C / -4 °F to 140 °F (application-dependent)
- Fully compatible with modern Ethernet networks and DCS communication
- Storage of up to 2,500 chromatograms, including sample calibration and validation streams