Specifications
- Warranty
- Up to 5-year limited warranty
- Rangedown
- Up To 100:1
- Measurement Range
- Up to 2000 psi (137,9 bar) differential
- Output
- Differential pressure, scaled variable
- Communication Protocol
- 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V Low Power HART®
- Process Wetted Material
- 316L SST, Alloy C-276, Tantalum
- Diagnostics
- Basic Diagnostics
- Certifications/Approvals
- SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE®, hazardous location, see full specs for complete list of certifications
Features
- Available pre-assembled to primary elements for an installation-ready flow solution that ensures reliable performance
- Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
- Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
- Performance up to 0.05% of span accuracy
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations