range of product |
Altivar Machine ATV340
|
|
---|---|---|
product or component type |
Variable speed drive
|
|
device application |
Machine
|
|
device short name |
ATV340
|
|
variant |
Standard version
|
|
product destination |
Asynchronous motors
Synchronous motors |
|
type of cooling |
Forced convection
|
|
supply frequency |
50…60 Hz +/- 5 %
|
|
network number of phases |
3 phases
|
|
[Us] rated supply voltage |
380…480 V – 15…10 %
|
|
motor power kW |
22 kW for normal duty
18.5 kW for heavy duty |
|
apparent power |
33.4 kVA at 480 V (normal duty)
36.1 kVA at 480 V (heavy duty) |
|
communication port protocol |
Modbus serial
|
|
IP degree of protection |
IP20
|
|
nominal output current |
39.0 A
|
|
relative symmetric network frequency tolerance |
5 %
|
|
relative symmetric mains voltage tolerance |
10 %
|
mounting mode |
Cabinet mount
|
|
---|---|---|
motor power hp |
30 hp for normal duty
25 hp for heavy duty |
|
line current |
54.7 A at 380 V without line choke (heavy duty)
43.4 A at 480 V without line choke (heavy duty) 49.9 A at 380 V with external line choke (normal duty) 40.2 A at 480 V with external line choke (normal duty) 54.5 A at 480 V with external line choke (heavy duty) 43.5 A at 380 V with external line choke (heavy duty) |
|
prospective line Isc |
22 kA
|
|
continuous output current |
46 A at 4 kHz for normal duty
39 A at 4 kHz for heavy duty |
|
maximum transient current |
50.6 A during 60 s (normal duty)
59 A during 60 s (heavy duty) 62.1 A during 2 s (normal duty) 70 A during 2 s (heavy duty) |
|
asynchronous motor control profile |
Optimized torque mode
Variable torque standard Constant torque standard |
|
synchronous motor control profile |
Reluctance motor
Permanent magnet motor |
|
speed drive output frequency |
0.1…599 Hz
|
|
nominal switching frequency |
4 kHz
|
|
switching frequency |
2…16 kHz adjustable
4…16 kHz with derating factor |
|
safety function |
STO (safe torque off) SIL 3
|
|
number of preset speeds |
16 preset speeds
|
|
output voltage |
<= power supply voltage
|
|
motor slip compensation |
Adjustable
Automatic whatever the load Can be suppressed Not available in permanent magnet motor law |
|
acceleration and deceleration ramps |
S, U or customized
Linear adjustable separately from 0.01…9999 s |
|
braking to standstill |
By DC injection
|
|
protection type |
Thermal protection: motor
Safe torque off: motor Motor phase loss: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive Motor phase loss: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Exceeding limit speed: drive Break on the control circuit: drive |
|
electrical connection |
Control: screw terminal0.2…2.5 mm²/AWG 24…AWG 12
Line side: screw terminal10…25 mm²/AWG 8…AWG 3 DC bus: screw terminal10…25 mm²/AWG 8…AWG 3 Motor: screw terminal6…25 mm²/AWG 8…AWG 3 |
|
connector type |
connector(s)1 x RJ45, Modbus serial on front face
connector(s)1 x RJ45, Modbus serial for HMI on front face |
|
physical interface |
2-wire RS 485 for Modbus serial
|
|
transmission frame |
RTU for Modbus serial
|
|
transmission rate |
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus serial
|
|
number of addresses |
1…247
|
|
data format |
8 bits, configurable odd, even or no parity for Modbus serial
|
|
method of access |
Slave Modbus RTU
|
|
supply |
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
|
width |
180.0 mm
|
|
height |
385.0 mm
|
|
depth |
249.0 mm
|
|
net weight |
10.2 kg
|
|
analogue input number |
2
|
|
analogue input type |
AI1 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI1 software-configurable temperature probe or water level sensor AI1 software-configurable voltage: 0…10 V DC, impedance: 31.5 kOhm, resolution 12 bits AI2 software-configurable voltage: – 10…10 V DC, impedance: 20 kOhm, resolution 12 bits |
|
discrete input number |
5
|
|
discrete input type |
PTI programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm DI1…DI5 programmable, 24 V DC (<= 30 V), impedance: 4.4 kOhm |
|
input compatibility |
DI1…DI5: discrete input level 1 PLC conforming to EN/IEC 61131-2
PTI: pulse input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
|
discrete input logic |
Positive logic (source) (DI1…DI5), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1…DI5), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (PTI), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
|
analogue output number |
2
|
|
analogue output type |
Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1: 0…20 mA impedance 500 Ohm, resolution 10 bits |
|
discrete output number |
2.0
|
|
input/output type |
Programmable as logic input/output DQ1: 0…1 kHz, <= 30 V DC, 100 mA
Programmable as logic input/output DQ2: 0…1 kHz, <= 30 V DC, 100 mA |
|
relay output number |
2
|
|
relay output type |
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles |
|
minimum switching current |
Relay output R1, R2: 5 mA at 24 V DC
|
|
maximum switching current |
Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2 on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2 on resistive load, cos phi = 1: 5 A at 30 V DC Relay output R2 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R2 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
|
isolation |
Between power and control terminals
|
|
insulation resistance |
> 1 MOhm 500 V DC for 1 minute to earth
|
|
noise level |
56.7 dB conforming to 86/188/EEC
|
|
power dissipation in W |
Natural convection: 21 W at 380 V, switching frequency 4 kHz (heavy duty)
Forced convection: 410 W at 380 V, switching frequency 4 kHz (heavy duty) Natural convection: 23 W at 380 V, switching frequency 4 kHz (normal duty) Forced convection: 464 W at 380 V, switching frequency 4 kHz (normal duty) |
|
pollution degree |
2 conforming to EN/IEC 61800-5-1
|
|
vibration resistance |
1.5 mm peak to peak (f= 2…19 Hz) conforming to EN/IEC 60721-3-3 class 3M3
1 gn (f= 9…200 Hz) conforming to EN/IEC 60721-3-3 class 3M3 |
|
shock resistance |
15 gn for 11 ms, class 3M3 conforming to EN/IEC 60721-3-3
|
|
maximum output frequency |
0.599 kHz
|
|
ambient air temperature for operation |
-15…50 °C without current derating (heavy duty)
-15…40 °C without current derating (normal duty) |
|
environmental characteristic |
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 |
|
maximum input current |
54.7 A
|
|
Variable speed drive application selection |
Tower crane Hoisting
Other application Hoisting Grouping conveyor Material handling Palletizer – high performance Material handling Cutting – high accuracy Material working (wood, ceramic, stone, pvc, metal) Polishing Material working (wood, ceramic, stone, pvc, metal) Grinding Material working (wood, ceramic, stone, pvc, metal) Slitter Material working (wood, ceramic, stone, pvc, metal) Filling bottles – synchronized operation Packaging Feed conveyor – medium performance Packaging Grouping boxing Packaging Conveyor Packaging Elevator Packaging Other application Packaging Standard crane – hoist Hoisting Automatic storage / retrieval system Material handling Shrinking wrapping Packaging |
|
Motor power range AC-3 |
15…25 kW at 380…440 V 3 phases
15…25 kW at 480…500 V 3 phases |
|
motor starter type |
Variable speed drive
|
|
base load current at high overload |
39.0 A
|
|
base load current at low overload |
46.0 A
|
|
maximum output voltage |
480 V
|
volume of cooling air |
128.0 m3/h
|
|
---|---|---|
operating position |
Vertical +/- 10 degree
|
|
electromagnetic compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
|
ambient air temperature for storage |
-40…70 °C
|
|
operating altitude |
<= 1000 m without derating
|
|
product certifications |
CSA
TÜV REACH UL |
|
marking |
CE
|
|
noise level |
56.7 dB
|
|
ambient air transport temperature |
-40…70 °C
|
Package 1 Weight |
11.9 kg
|
|
---|---|---|
Package 2 Weight |
11.85 kg
|
|
Package 3 Weight |
36.8 kg
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
REACh Regulation |
REACh Declaration
|
|
EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration |
|
Mercury free |
Yes
|
|
RoHS exemption information |
Yes
|
|
China RoHS Regulation |
China RoHS declaration
|
|
Environmental Disclosure |
Product Environmental Profile
|
|
Circularity Profile |
End of Life Information
|
|
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
Warranty |
18 months
|
---|
There are no reviews yet.