ATS48D17Q

Schneider Electric

Soft starter for asynchronous motor

ATS48 – 14.8 A – 230..415 V – 3..15 KW

 

 

Compare
Main
range of product
Altistart 48
product or component type
Soft starter
product destination
Asynchronous motors
product specific application
Heavy duty industry and pumps
device short name
ATS48
power supply voltage
230…415 V – 15…10 %
motor power kW
7.5 kW at 230 V connection to the motor delta terminals for standard applications
7.5 kW at 400 V connection in the motor supply line for standard applications
11 kW at 400 V connection to the motor delta terminals for severe applications
15 kW at 400 V connection to the motor delta terminals for standard applications
3 kW at 230 V connection in the motor supply line for severe applications
4 kW at 230 V connection in the motor supply line for standard applications
5.5 kW at 230 V connection to the motor delta terminals for severe applications
5.5 kW at 400 V connection in the motor supply line for severe applications
power dissipation in W
46 W for severe applications
59 W for standard applications
utilisation category
AC-53A
type of start
Start with torque control (current limited to 5 In)
Icl nominal current
17 A for connection in the motor supply line for severe applications
17 A for connection in the motor supply line for standard applications
29 A for connection to the motor delta terminals for severe applications
29 A for connection to the motor delta terminals for standard applications
IP degree of protection
IP20
Complementary
assembly style
With heat sink
function available
External bypass (optional)
power supply voltage limits
195…456 V
power supply frequency
50…60 Hz – 5…5 %
power supply frequency limits
47.5…63 Hz
device connection
To the motor delta terminals
In the motor supply line
factory setting current
14.8 A
[Uc] control circuit voltage
220 – 15 % to 415 + 10 %, 50/60 Hz
control circuit consumption
30 W
discrete output number
2
discrete output type
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
output absolute accuracy precision
+/- 5 %
minimum switching current
10 mA at 6 V DC for relay outputs
maximum switching current
Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms
discrete input number
5
discrete input type
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input voltage
24 V <= 30 V
discrete input logic
Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
starting current
0.4…1.3 Icl adjustable
analogue output type
Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
communication port protocol
Modbus
connector type
1 RJ45
communication data link
Serial
physical interface
RS485 multidrop
transmission rate
4800, 9600 or 19200 bps
max nodes number
31
protection type
Phase failure: line
Thermal protection: motor
Thermal protection: starter
marking
CE
type of cooling
Natural convection
operating position
Vertical +/- 10 degree
height
275 mm
width
160 mm
depth
190 mm
net weight
4.9 kg
Motor power range AC-3
7…11 kW at 200…240 V 3 phases
7…11 kW at 380…440 V 3 phases
15…25 kW at 380…440 V 3 phases
2.2…3 kW at 200…240 V 3 phases
4…6 kW at 200…240 V 3 phases
4…6 kW at 380…440 V 3 phases
motor starter type
Soft starter
Environment
electromagnetic compatibility
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
standards
EN/IEC 60947-4-2
product certifications
UL
CCC
GOST
DNV
CSA
NOM 117
SEPRO
TCF
C-Tick
vibration resistance
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6
shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
pollution degree
Level 3 conforming to IEC 60664-1
relative humidity
0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
ambient air temperature for storage
-25…70 °C
operating altitude
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Package 1 Weight
5.682 kg
Package 2 Weight
58.456 kg
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty
18 months
Brands

Schneider Electric

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “ATS48D17Q”

There are no reviews yet.