<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Input and Output (I/O) Archives - İntegral Elektronik</title>
	<atom:link href="https://integralelektronik.com/product-category/omron/input-and-output-i-o/feed/" rel="self" type="application/rss+xml" />
	<link>https://integralelektronik.com/product-category/omron/input-and-output-i-o/</link>
	<description></description>
	<lastBuildDate>Wed, 18 Nov 2020 17:33:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://integralelektronik.com/wp-content/uploads/2021/06/cropped-3534b231-79c5-4019-8b9d-2bd4d90ac337-32x32.png</url>
	<title>Input and Output (I/O) Archives - İntegral Elektronik</title>
	<link>https://integralelektronik.com/product-category/omron/input-and-output-i-o/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GRT1-AD2</title>
		<link>https://integralelektronik.com/product/grt1-ad2/</link>
					<comments>https://integralelektronik.com/product/grt1-ad2/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 14 Nov 2020 20:11:06 +0000</pubDate>
				<guid isPermaLink="false">http://integralelektronik.com/?post_type=product&#038;p=6463</guid>

					<description><![CDATA[<h2>SmartSlice 2 x analog inputs,</h2>
<h3 class="subtitle">1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA, 4 to 20 mA, resolution 1:6000</h3>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://integralelektronik.com/product/grt1-ad2/">GRT1-AD2</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<h3></h3>
<table class="one">
<tbody>
<tr>
<td>I/O system</td>
<td>GRT1 I/O Bus</td>
</tr>
<tr>
<td>Type of module</td>
<td>Analog I/O</td>
</tr>
<tr>
<td>I/O connection type</td>
<td>Push-in</td>
</tr>
<tr>
<td>Number of analog inputs</td>
<td>2</td>
</tr>
<tr>
<td>Temperature input type</td>
<td>None</td>
</tr>
<tr>
<td>Linear analog input type</td>
<td>-10 to 10 V, 0 to 10 V, 0 to 20 mA, 0 to 5 V, 1 to 5 V, 4 to 20 mA</td>
</tr>
<tr>
<td>Resolution of the analog inputs</td>
<td>13 Bit</td>
</tr>
<tr>
<td>Number of analog outputs</td>
<td>0</td>
</tr>
<tr>
<td>Linear analog output type</td>
<td>None</td>
</tr>
<tr>
<td>Resolution of the analog outputs</td>
<td>0 Bit</td>
</tr>
<tr>
<td>Degree of protection (IP)</td>
<td>IP20</td>
</tr>
<tr>
<td>Height</td>
<td>84 mm</td>
</tr>
<tr>
<td>Width</td>
<td>15 mm</td>
</tr>
<tr>
<td>Depth</td>
<td>74.4 mm</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://integralelektronik.com/product/grt1-ad2/">GRT1-AD2</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://integralelektronik.com/product/grt1-ad2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GRT1-DRT</title>
		<link>https://integralelektronik.com/product/grt1-drt/</link>
					<comments>https://integralelektronik.com/product/grt1-drt/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 14 Nov 2020 20:11:03 +0000</pubDate>
				<guid isPermaLink="false">http://integralelektronik.com/?post_type=product&#038;p=6462</guid>

					<description><![CDATA[<h2>SmartSlice communication adaptor for DeviceNet,</h2>
<h3 class="subtitle">connects up to 64 GRT1 I/O units (End plate to be ordered separately)</h3>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://integralelektronik.com/product/grt1-drt/">GRT1-DRT</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<h3></h3>
<table class="one">
<tbody>
<tr>
<td>I/O system</td>
<td>GRT1 I/O Bus</td>
</tr>
<tr>
<td>Type of module</td>
<td>Bus coupler</td>
</tr>
<tr>
<td>Communication port(s)</td>
<td>DeviceNet Slave</td>
</tr>
<tr>
<td>Degree of protection (IP)</td>
<td>IP20</td>
</tr>
<tr>
<td>Height</td>
<td>84 mm</td>
</tr>
<tr>
<td>Width</td>
<td>58 mm</td>
</tr>
<tr>
<td>Depth</td>
<td>70 mm</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://integralelektronik.com/product/grt1-drt/">GRT1-DRT</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://integralelektronik.com/product/grt1-drt/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GI-S Series</title>
		<link>https://integralelektronik.com/product/gi-s-series/</link>
					<comments>https://integralelektronik.com/product/gi-s-series/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 14 Nov 2020 20:11:01 +0000</pubDate>
				<guid isPermaLink="false">http://integralelektronik.com/?post_type=product&#038;p=6461</guid>

					<description><![CDATA[<h2>Safety I/O Terminals for CIP Safety™</h2>
<ul>
<li>
<h3>Safety Remote Digital Blocs</h3>
</li>
<li>
<h3>Individual Test Pulses for better diagnostics</h3>
</li>
<li>
<h3>CIP-Safety on EtherNet/IP is Supported</h3>
</li>
<li>
<h3>Standard-feature EtherNet/IP Communications Port</h3>
</li>
<li>
<h3>Separate Power supply for Logic and S-I/O's</h3>
</li>
<li>
<h3>Can work as remote Safety I/O's in combination with NX-SL5000 series with NX-CSG320 or NX102 using port 2 A/B</h3>
</li>
</ul>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://integralelektronik.com/product/gi-s-series/">GI-S Series</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="page-width">
<h2>Specifications &amp; ordering info</h2>
</div>
<div class="framemaker xml">
<section>
<h1>Ordering information</h1>
<table frame="bottom">
<thead>
<tr>
<th colspan="3">Specifications</th>
<th colspan="3">I/O capacity</th>
<th rowspan="2">Unit version</th>
<th rowspan="2">Order code</th>
</tr>
<tr>
<th>Communication protocol</th>
<th>Number of connectors</th>
<th>Number of networks</th>
<th>Safety inputs</th>
<th>Pulse outputs</th>
<th>Safety outputs<br />
(for PNP)</th>
</tr>
</thead>
<tbody>
<tr>
<td rowspan="2">EtherNet/IP</td>
<td rowspan="2">2</td>
<td rowspan="2">1</p>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
<td rowspan="2">12 inputs</td>
<td rowspan="2">12 outputs</td>
<td>4 outputs</td>
<td rowspan="2">Ver. 1.2</td>
<td>GI-SMD1624</td>
</tr>
<tr>
<td>–</td>
<td>GI-SID1224</td>
</tr>
</tbody>
</table>
</section>
<section>
<h1>Specifications</h1>
<section>
<h2>Regulations and Standards</h2>
<section>
<h3>GI-S-series safety I/O terminals</h3>
<table frame="bottom">
<thead>
<tr>
<th>Certification body</th>
<th>Standards</th>
</tr>
</thead>
<tbody>
<tr>
<td>TÜV Rheinland</td>
<td>EN ISO 13849-1IEC 61508 parts 1-7IEC/EN 62061IEC/EN 61131-2</td>
</tr>
<tr>
<td>UL</td>
<td>NRAQ (UL61010-1, and UL 61010-2-201)NRAG (UL 121201)NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201)</td>
</tr>
</tbody>
</table>
<p>The FSoE protocol was certified for applications in which OMRON FSoE devices are connected to each other. For compatibility with FSoE devices other than OMRON FSoE devices, the customer must validate FSoE communications.</p>
<p>By using GI-S-series safety I/O terminals, you can build a safety control system that meets the followings.<br />
&#8211; Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, IEC/EN 62061, (Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems)<br />
&#8211; Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1Also, GI-S-series safety I/O terminals have been registered for conformity to RCM, EAC, and KC (Korean radio regulation).</p>
</section>
</section>
<section>
<h2>General Specifications</h2>
<table frame="bottom">
<thead>
<tr>
<th colspan="2">Item</th>
<th>Specifications</th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="2">Enclosure</td>
<td>Mounted in a panel (open type)</td>
</tr>
<tr>
<td rowspan="13">Operating environment</td>
<td>Ambient operating temperature</td>
<td>0 to 55°C</td>
</tr>
<tr>
<td>Ambient operating humidity</td>
<td>10% to 95% (with no condensation or icing)</td>
</tr>
<tr>
<td>Atmosphere</td>
<td>Must be free from corrosive gases</td>
</tr>
<tr>
<td>Ambient storage temperature</td>
<td>−25 to 70°C (with no condensation or icing)</td>
</tr>
<tr>
<td>Altitude</td>
<td>2,000 m max.</td>
</tr>
<tr>
<td>Pollution degree</td>
<td>2</td>
</tr>
<tr>
<td>Insulation class</td>
<td>CLASS III (SELV)</td>
</tr>
<tr>
<td>Overvoltage category</td>
<td>II</td>
</tr>
<tr>
<td>EMC immunity level</td>
<td>Zone B: IEC 61131-2</td>
</tr>
<tr>
<td>Vibration resistance</td>
<td>Conforms to IEC 60068-2-6<br />
5 to 8.4 Hz with amplitude of 3.5 mm<br />
8.4 to 150 Hz, acceleration of 9.8 m/s<sup>2</sup><br />
100 min. in each X, Y, and Z directions (10 sweeps of 10 min. each = 100 min. total)</td>
</tr>
<tr>
<td>Shock resistance</td>
<td>Conforms to IEC 60068-2-27<br />
147 m/s<sup>2</sup><br />
3 times in each X, Y, and Z directions</td>
</tr>
<tr>
<td>Insulation resistance</td>
<td>20 MΩ between isolated circuits (at 100 VDC)</td>
</tr>
<tr>
<td>Dielectric strength</td>
<td>500 VAC between isolated circuits for 1 minute at a leakage current of 10 mA max.</td>
</tr>
<tr>
<td colspan="2">Installation method</td>
<td>DIN Track mounting (IEC 60715 TH35-7.5/TH35-15)</td>
</tr>
<tr>
<td colspan="2">Degree of protection</td>
<td>IP20</td>
</tr>
</tbody>
</table>
</section>
<section>
<h2>GI-SMD1624/GI-SID1224</h2>
<table frame="bottom">
<thead>
<tr>
<th colspan="2">Model</th>
<th>GI-SMD1624</th>
<th>GI-SID1224</th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="2">Number of safety input points</td>
<td colspan="2">12</td>
</tr>
<tr>
<td colspan="2">Number of safety output points</td>
<td>4</td>
<td>–</td>
</tr>
<tr>
<td colspan="2">Number of test output points</td>
<td colspan="2">12</td>
</tr>
<tr>
<td colspan="2">OMRON special safety input device</p>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
<td colspan="2">Connection unavailable</td>
</tr>
<tr>
<td colspan="2">LED indication</td>
<td>[V0] LED, [IN⬜] LED x 12, [V1] LED,<br />
[OUT⬜] LED x 4, [MS] LED, [NS] LED,<br />
[PORT⬜LINK] LED x 2</td>
<td>[V0] LED, [IN⬜] LED x 12,<br />
[V1] LED, [MS] LED, [NS] LED,<br />
[PORT⬜LINK] LED x 2</td>
</tr>
<tr>
<td colspan="2">Hardware switch setting</td>
<td colspan="2">[IP ADDRESS] switch x3 (MODE, x16, x1)</p>
<p><img decoding="async" src="https://product-details.s3.eu-west-1.amazonaws.com/IP_ADDRESS.png" />Factory default<br />
GI-SMD1624: 192.168.250.2 [IP ADDRESS] Switch= “002”<br />
GI-SID1224: 192.168.250.3 [IP ADDRESS] Switch= “003“</td>
</tr>
<tr>
<td colspan="2">Safety input type</td>
<td colspan="2">IEC61131-2 type3 PNP (sinking inputs)</td>
</tr>
<tr>
<td colspan="2">Safety input current</td>
<td colspan="2">6 mA max.</td>
</tr>
<tr>
<td colspan="2">Safety input ON voltage</td>
<td colspan="2">11 VDC min.</td>
</tr>
<tr>
<td colspan="2">Safety input OFF voltage/OFF current</td>
<td colspan="2">5 VDC max./1 mA max.</td>
</tr>
<tr>
<td colspan="2">Safety output type</td>
<td colspan="2">Source output (for PNP)</td>
</tr>
<tr>
<td colspan="2">Safety output rated current</td>
<td>0.5 A max.</td>
<td rowspan="5">
<div class="tooltip"><a class="footnote">2</a></div>
</td>
</tr>
<tr>
<td colspan="2">Maximum total safety output current</td>
<td>2.0 A</td>
</tr>
<tr>
<td colspan="2">Safety output ON residual voltage</td>
<td>1.2 V max.<br />
(between V1 and each output terminal)</td>
</tr>
<tr>
<td colspan="2">Safety output OFF residual voltage</td>
<td>2.0 V max.<br />
(between G1 and each output terminal)</td>
</tr>
<tr>
<td colspan="2">Safety output leakage current</td>
<td>0.1 mA max.</td>
</tr>
<tr>
<td colspan="2">Test output type</td>
<td colspan="2">Source output (for PNP)</td>
</tr>
<tr>
<td colspan="2">Test output rated current</td>
<td colspan="2">0.7 A max.</td>
</tr>
<tr>
<td colspan="2">Maximum total test output current</td>
<td colspan="2">5.0 A</td>
</tr>
<tr>
<td colspan="2">Test output ON residual voltage</td>
<td colspan="2">1.2 V max. (between V0 and each output terminal)</td>
</tr>
<tr>
<td colspan="2">Test output leakage current</td>
<td colspan="2">0.1 mA max.</td>
</tr>
<tr>
<td colspan="2">External dimensions</p>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
<td colspan="2">170 (W) x 65 (H) x 55 (D)</td>
</tr>
<tr>
<td colspan="2">Weight</td>
<td colspan="2">400 g</td>
</tr>
<tr>
<td colspan="2">Number of communications that can be set<br />
between NX Units</td>
<td colspan="2">254 ports max.</p>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
</tr>
<tr>
<td rowspan="5">Unit power<br />
supplies</td>
<td>Power supply voltage</td>
<td colspan="2">24 VDC (20.4 to 28.8 VDC)</td>
</tr>
<tr>
<td>Current consumption</p>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
<td colspan="2">250 A max.</td>
</tr>
<tr>
<td>Inrush current</td>
<td colspan="2">On cold start at normal temperature50 A max., 0.1 ms max.</td>
</tr>
<tr>
<td>Power supply terminal<br />
current carrying capacity</p>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
<td colspan="2">5 A</td>
</tr>
<tr>
<td>Insulation type</td>
<td colspan="2">No insulation: Between unit power supply terminal and internal circuit</td>
</tr>
<tr>
<td rowspan="5">Output power<br />
supply</td>
<td>Power supply voltage</td>
<td>24 VDC (20.4 to 28.8 VDC)</td>
<td rowspan="5">
<div class="tooltip"><a class="footnote">2</a></div>
</td>
</tr>
<tr>
<td>Current consumption</td>
<td>50 A max.</td>
</tr>
<tr>
<td>Inrush current</td>
<td>On cold start at normal temperature<br />
50 A max., 0.1 ms max.</td>
</tr>
<tr>
<td>Power supply terminal<br />
current carrying capacity</p>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
<td>5 A</td>
</tr>
<tr>
<td>Insulation type</td>
<td>Photocoupler insulation</td>
</tr>
<tr>
<td rowspan="2">External<br />
connection<br />
terminal</td>
<td>Communication connector</td>
<td colspan="2">EtherNet/IP communication RJ45 x 2</td>
</tr>
<tr>
<td>Screwless clamp terminal<br />
block</td>
<td>Top terminal block</p>
<ul>
<li>Functional earthing</li>
<li>Unit power supply</li>
<li>Input/Test output</li>
</ul>
<p>Bottom terminal block</p>
<ul>
<li>Output power supply</li>
<li>Output/Input/Test output</li>
</ul>
</td>
<td>Top terminal block</p>
<ul>
<li>Functional earthing</li>
<li>Unit power supply</li>
<li>Input/Test output</li>
</ul>
<p>Bottom terminal block</p>
<ul>
<li>Input/Test output</li>
</ul>
</td>
</tr>
<tr>
<td rowspan="2">Inter-terminal<br />
connection<br />
diagram</td>
<td>V0/G0 Unit power supply</td>
<td colspan="2"><img decoding="async" src="https://product-details.s3.eu-west-1.amazonaws.com/tanshi_setuzoku-1.png" /></td>
</tr>
<tr>
<td>V1/G1 Output power supply</td>
<td><img decoding="async" src="https://product-details.s3.eu-west-1.amazonaws.com/tanshi_setuzoku-2.png" /></td>
<td>
<div class="tooltip"><a class="footnote">2</a></div>
</td>
</tr>
<tr>
<td colspan="2">Installation direction and restriction</td>
<td colspan="2">No restriction</td>
</tr>
<tr>
<td colspan="2">Protective function</td>
<td colspan="2">Overvoltage protection, overcurrent protection</td>
</tr>
</tbody>
</table>
</section>
<section>
<h2>Built-in EtherNet/IP port specifications</h2>
<p>This section describes the field bus specifications of the safety I/O terminal.</p>
<table frame="bottom">
<thead>
<tr>
<th colspan="2" rowspan="2">Item</th>
<th>Specifications</th>
</tr>
<tr>
<th>GI-SMD1624 / GI-SID1224</th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="2">Communications protocol</td>
<td>TCP/IP, UDP/IP</td>
</tr>
<tr>
<td colspan="2">Support services</td>
<td>Sysmac Studio connection, CIP message communication, DHCP (client)</td>
</tr>
<tr>
<td colspan="2">Number of logical ports</td>
<td>2</td>
</tr>
<tr>
<td colspan="2">Physical layer</td>
<td>100BASE-TX</td>
</tr>
<tr>
<td rowspan="6">Transmission specifications</td>
<td>Media access method</td>
<td>CSMA/CD</td>
</tr>
<tr>
<td>Modulation</td>
<td>Baseband</td>
</tr>
<tr>
<td>Transmission path</td>
<td>Star, daisy chain, mixed (star and daisy chain)</td>
</tr>
<tr>
<td>Transmission rate</td>
<td>100M bit/s (100BASE-TX)</td>
</tr>
<tr>
<td>Transmission media</td>
<td>Twisted-pair cable (shielded: STP): category 5/5e or higher</td>
</tr>
<tr>
<td>Transmission distance</td>
<td>100 m max. (distance between hub and node)</td>
</tr>
<tr>
<td colspan="2">Number of daisy chain connections</td>
<td>8 units</td>
</tr>
<tr>
<td colspan="2">CIP messaging service:<br />
Explicit message<br />
UCMM (non-connection type)</td>
<td>Maximum number of clients that can communicate simultaneously: 8/Logical ports</td>
</tr>
<tr>
<td>Implicit (I/O) connection</td>
<td>Exclusive Owner (EO) connection</td>
<td>1</td>
</tr>
<tr>
<td colspan="2">EtherNet/IP conformance test</td>
<td>CT9 compliant</td>
</tr>
<tr>
<td colspan="2">Ethernet interface</td>
<td>100BASE-TX</p>
<p>Auto Negotiation</p>
<p>Auto-MDI</td>
</tr>
</tbody>
</table>
</section>
<section>
<h2>Version Information</h2>
<p>This section describes the combinations that can be used of the unit versions of the Safety CPU Unit and the Communication Control Unit, Machine Automation Controller, and the version of the Sysmac Studio.</p>
<table frame="bottom">
<thead>
<tr>
<th colspan="2">Safety I/O terminal</th>
<th colspan="4">Corresponding unit version/version</th>
</tr>
<tr>
<th>Model</th>
<th>Unit version</th>
<th>Safety CPU Unit</p>
<p>NX-SL5700<br />
NX-SL5500</th>
<th>Communication Control Unit</p>
<p>NX-CSG320</th>
<th>Machine Automation Controller</p>
<p>NX102-⬜⬜⬜⬜</th>
<th>Sysmac Studio</th>
</tr>
</thead>
<tbody>
<tr>
<td>GI-SMD1624</td>
<td>Ver. 1.2</td>
<td>Ver. 1.3</td>
<td>Ver. 1.01</td>
<td>Ver. 1.31</td>
<td>Ver. 1.24</td>
</tr>
<tr>
<td>GI-SID1224</td>
<td>Ver. 1.2</td>
<td>Ver. 1.3</td>
<td>Ver. 1.01</td>
<td>Ver. 1.31</td>
<td>Ver. 1.24</td>
</tr>
</tbody>
</table>
</section>
</section>
</div>
<p>The post <a href="https://integralelektronik.com/product/gi-s-series/">GI-S Series</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://integralelektronik.com/product/gi-s-series/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NX-AD4203</title>
		<link>https://integralelektronik.com/product/nx-ad4203/</link>
					<comments>https://integralelektronik.com/product/nx-ad4203/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 14 Nov 2020 20:10:55 +0000</pubDate>
				<guid isPermaLink="false">http://integralelektronik.com/?post_type=product&#038;p=6460</guid>

					<description><![CDATA[<h2>8 Analog Inputs,</h2>
<h3 class="subtitle">4 to 20 mA single ended, resolution 1:8000, 250 µs/ch, screwless push-in connector, 12 mm wide</h3>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://integralelektronik.com/product/nx-ad4203/">NX-AD4203</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<h3></h3>
<table class="one">
<tbody>
<tr>
<td>I/O system</td>
<td>NX I/O Bus</td>
</tr>
<tr>
<td>Type of module</td>
<td>Analog I/O</td>
</tr>
<tr>
<td>Number of analog inputs</td>
<td>8</td>
</tr>
<tr>
<td>Temperature input type</td>
<td>None</td>
</tr>
<tr>
<td>Linear analog input type</td>
<td>4 to 20 mA</td>
</tr>
<tr>
<td>Resolution of the analog inputs</td>
<td>13 Bit</td>
</tr>
<tr>
<td>Input circuit type</td>
<td>Single-ended</td>
</tr>
<tr>
<td>Number of analog outputs</td>
<td>0</td>
</tr>
<tr>
<td>Linear analog output type</td>
<td>None</td>
</tr>
<tr>
<td>Conversion time</td>
<td>2 ms/unit</td>
</tr>
<tr>
<td>Signal processing</td>
<td>Free running</td>
</tr>
<tr>
<td>IO link master</td>
<td>&#8211;</td>
</tr>
<tr>
<td>I/O connection type</td>
<td>Push-in</td>
</tr>
<tr>
<td>Number of I/O connectors</td>
<td>1</td>
</tr>
<tr>
<td>Detachable I/O connector</td>
<td>+</td>
</tr>
<tr>
<td>Suitable for safety functions</td>
<td>&#8211;</td>
</tr>
<tr>
<td>SIL according to IEC 61508</td>
<td>None</td>
</tr>
<tr>
<td>Degree of protection (IP)</td>
<td>IP20</td>
</tr>
<tr>
<td>Height</td>
<td>100 mm</td>
</tr>
<tr>
<td>Width</td>
<td>12 mm</td>
</tr>
<tr>
<td>Depth</td>
<td>71 mm</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://integralelektronik.com/product/nx-ad4203/">NX-AD4203</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://integralelektronik.com/product/nx-ad4203/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NX-AD3604</title>
		<link>https://integralelektronik.com/product/nx-ad3604/</link>
					<comments>https://integralelektronik.com/product/nx-ad3604/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 14 Nov 2020 20:09:25 +0000</pubDate>
				<guid isPermaLink="false">http://integralelektronik.com/?post_type=product&#038;p=6457</guid>

					<description><![CDATA[<h2>4 Analog Inputs,</h2>
<h3 class="subtitle">10 to 10 V differential, resolution 1:8000, 250 µs/ch, screwless push-in connector, 12 mm wide</h3>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://integralelektronik.com/product/nx-ad3604/">NX-AD3604</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<h3></h3>
<table class="one">
<tbody>
<tr>
<td>I/O system</td>
<td>NX I/O Bus</td>
</tr>
<tr>
<td>Type of module</td>
<td>Analog I/O</td>
</tr>
<tr>
<td>Number of analog inputs</td>
<td>4</td>
</tr>
<tr>
<td>Temperature input type</td>
<td>None</td>
</tr>
<tr>
<td>Linear analog input type</td>
<td>-10 to 10 V</td>
</tr>
<tr>
<td>Resolution of the analog inputs</td>
<td>13 Bit</td>
</tr>
<tr>
<td>Input circuit type</td>
<td>Differential</td>
</tr>
<tr>
<td>Number of analog outputs</td>
<td>0</td>
</tr>
<tr>
<td>Linear analog output type</td>
<td>None</td>
</tr>
<tr>
<td>Conversion time</td>
<td>1 ms/unit</td>
</tr>
<tr>
<td>Signal processing</td>
<td>Free running</td>
</tr>
<tr>
<td>IO link master</td>
<td>&#8211;</td>
</tr>
<tr>
<td>I/O connection type</td>
<td>Push-in</td>
</tr>
<tr>
<td>Number of I/O connectors</td>
<td>1</td>
</tr>
<tr>
<td>Detachable I/O connector</td>
<td>+</td>
</tr>
<tr>
<td>Suitable for safety functions</td>
<td>&#8211;</td>
</tr>
<tr>
<td>SIL according to IEC 61508</td>
<td>None</td>
</tr>
<tr>
<td>Degree of protection (IP)</td>
<td>IP20</td>
</tr>
<tr>
<td>Height</td>
<td>100 mm</td>
</tr>
<tr>
<td>Width</td>
<td>12 mm</td>
</tr>
<tr>
<td>Depth</td>
<td>71 mm</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://integralelektronik.com/product/nx-ad3604/">NX-AD3604</a> appeared first on <a href="https://integralelektronik.com">İntegral Elektronik</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://integralelektronik.com/product/nx-ad3604/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
